Abstract
A new method for the determination of the selectivity coefficient of an ion selective electrode is proposed. In the proposed method, a series of mixed solutions of the primary ion i and interfering ion j is prepared in which the sum of the logarithm of i concentration and logarithm of j concentration is kept constant. The potential of the electrode, E, is measured for the series of the mixed solutions. The result is plotted with the activity of i, ai, as abscissa against E on semi-logarithmic graph paper. The activity at the intersection of two extrapolated linear parts of the log a1-E curve is determined. From the activity at the intersection of the primary ion, the selectivity coefficient is calculated. The proposed method was applied to the determination of selectivity coefficients of fluoride, chloride, bromide and potassium selective electrodes. The selectivity coefficients determined by the proposed method, named “continuous variation method”, agreed with those obtained with the conventional mixed solution method.
Access options
Buy single article
Instant access to the full article PDF.
39,95 €
Price
includes VAT [Singapore]
References
S. Okazaki and H. Freiser, Denki Kagaku oyobi Kogyo Butsuri Kagaku, 50, No. 1, 117 [1982].
Article CAS Google Scholar
C. Macca and M. Cakrt, Anal Chim. Acta, 154, 51, [1983].
Article CAS Google Scholar
V. P. Y. Gadzekpo and G. D. Christian, Anal. Chim. Acta, 164, 279 [1984].
Article CAS Google Scholar
G. J. Moody and J. D. R. Thomas, “Selective Ion-Sensitive Electrodes”, p. 14, Merrow Pub. Co., Ltd., New York [1971].
Google Scholar
G. J. Moody and J. D. R. Thomas, “Selective Ion-Sensitive Electrodes”, p. 7, Legend of Fig. 4, Merrow Pub. Co., Ltd., New York [1971].
Google Scholar
Download references
Author information
Authors and Affiliations
Government Industrial Research Institute, Osaka, Ikeda, Osaka, 563, Japan
Kazuo Hiiro, Shin-ichi Wakida & Masataka Yamane
Authors
- Kazuo Hiiro
You can also search for this author in PubMed Google Scholar
- Shin-ichi Wakida
You can also search for this author in PubMed Google Scholar
- Masataka Yamane
You can also search for this author in PubMed Google Scholar
Rights and permissions
About this article
Cite this article
Hiiro, K., Wakida, Si. & Yamane, M. Determination of Selectivity Coefficients of Ion Selective Electrodes by Continuous Variation Method. ANAL. SCI. 4, 149–151 [1988]. //doi.org/10.2116/analsci.4.149
Download citation
Received: 23 October 1987
Accepted: 15 February 1988
Published: 25 April 1988
Issue Date: April 1988
DOI: //doi.org/10.2116/analsci.4.149
Keywords
- Selectivity coefficient
- continuous variation method
- ion selective electrode
We apologize for the inconvenience...
...but your activity and behavior on this site made us think that you are a bot.
Note: A number of things could be going on here.
- If you are attempting to access this site using an anonymous Private/Proxy network, please disable that and try accessing site again.
- Due to previously detected malicious behavior which originated from the network you're using, please request unblock to site.
In general, it is a common feature of all analysis methods that when atoms or ions of a different species but with similar properties are also present, i.e. coexist with the atoms or ions of interest, they interfere with measurement.
This is also true of analysis using ion selective electrodes [which we refer to as the ion electrode method], so that if ions similar to the target ions are present, they will—to a greater or lesser extent—affect measurement.
When considered
in contrast to the target ions, these ions are known as interfering ions. The intensity of the interference produced by an ion species is expressed by the selectivity coefficient [or by the maximum allowable coexistence factor, this roughly corresponding to the reciprocal of the selectivity coefficient]. The “What are Ion electrodes?” section states that the
pH-sensitive glass electrode can be regarded as a hydrogen ion [H+] electrode. pH-sensitive glass electrodes are largely not affected by coexisting ions, but the “Measurement for strongly acidic/basic aqueous solution” section in “Measurement of pH” mentions that measurements of samples with a pH over 12 suffer from a certain
level of error [called alkaline error]. Alkaline error indicates that, in addition to responding to H+ ions, pH-sensitive glass electrodes are also affected to some degree by alkaline metal ions [such as Na+ and K+].
Do you recall the periodical table? Each column contains elements with similar properties. For example, Li, Na, and K etc. are the alkaline metals, which tend to form monovalent cations; Mg and Ca etc. are the alkaline-earth metals, which tend to form divalent cations; and F,
Cl, Br, and I etc. are the halogens, which tend to form monovalent anions. In addition, the elements Cu, Ag, Cd, and Pb, which tend to form monovalent and divalent cations, are aligned relatively close to each other both vertically and horizontally within the table.
When using the ion electrode method, care needs to be taken with regard to mutual interference within each of these groups.
In addition, the effects of coexisting ions can be predicted to some extent from the response membrane material, that is to say, the reactivity of the response membrane material to the coexisting ions. For example, a solid-state membrane electrode can be seriously affected by coexisting ions that form insoluble compounds or complex salts with the material of its response membrane; and a liquid membrane electrode can be affected by coexisting ions that form ionic associates with the components in its response membrane.
Example: Impact of coexisting ions on potassium ions
A potassium ion electrode can be affected by various types of ion species. The degree of this effect can be expressed by using selectivity coefficient K in the following formula:
where aK+ is the potassium ion concentration, and ax is the interfering ion concentration. The smaller the value of K, the less the interference. The selectivity coefficients of typical interfering ions are listed in the table below. Please note that the selectivity coefficient varies depending on potassium ion concentration. The values in the table are for 10-3mol/L K+. The larger the potassium ion concentration, the less the interference.
Rb+ | 1×10-1 |
Mg2+ | 1×10-5 |
NH4+ | 7×10-3 |
Ca2+ | 7×10-7 |
Cs+ | 4×10-3 |
Na+ | 3×10-4 |
pH = 2 to 9 [at 10-3mol/L K+]
For reference: Definition of selectivity coefficient
The Nicolsky-Eisenman equation defines the selectivity coefficient
where ai represents the activity of an ion other than the target ion denoted by i, and
“Handbook on Electrochemistry,” 4th ed., Electrochemical Society of Japan, Maruzen, 1985, p. 209
Hence, in practice, the ratio of target ion to interfering ion concentration is very important. Higher concentrations of target ions result in the interfering ions having a smaller effect, and conversely, lower concentrations result in them having a larger effect.
An ion selective electrode has its own operable pH range. This range is itself determined by the two following ranges: [1] the range in which the ion electrode is not affected by
hydrogen ions H+ or hydroxyl-ions OH-, and [2] the range in which the target ions can exist as ions. For example, to a greater or lesser extent, metal ions tend to form hydroxides, not free ions, in the alkaline region. In practice, the pH range in which an ion electrode maintains a constant electromotive force is measured by changing the pH of a target ion reference solution of fixed concentration [such as 10-3mol/L or 10-4mol/L] from acidic to alkaline. These measured pH ranges are stated in
the relevant catalogs. Our ion selective electrode catalogs show as much information as possible regarding the selectivity coefficients and maximum allowable coexistence factors of interfering ions.
Relation page Measurement of Ion